TORD4-63 2P 63A 10mA A/AC Type Residual Current Circuit Breaker RCCB RCD

TONGOU

1. Provides protection against earth fault/leakage current and function of isolation.

2. High short-circuit current withstand capacity.

3. Applicable to terminal and pin/fork type busbar connection.

Description

4. Approved over-entering and down-entering connection.

5. Automatically disconnect the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity.

6. Independent of power supply and line voltage, and free from external interference, voltage fluctuation.

Residual Current Circuit Breaker is applicable to electric circuits with rated voltage 230/400V AC, frequency 50/60Hz and rated current up to 125Amp.
The RCCB provides indirect protection to the operator’s body under such condition that the exposed live parts
should be connected to a proper earthing pole.The RCCB also provides protection against the fire danger caused
by earth fault current due to function failure of over-current protection device.
Special tips:
1. RCCB with rated sensitivity up to 10mA could be used as supplementary protecting device in case other
protecting device fails its protection against electric shock.
2. RCCB designed for household installation and other similar application, is for non-professional operation,
and no maintenance is required.
3. RCCB provides on protection against electric shock resulted from direct contacts of both protected lines,or
leakage current between these two lines.
4. Particular devices such as surge protective devices,surge arrester etc are recommended to install at upstream line to RCCB as precaution against potential surge voltage and current occurring at its power input side.
5. Satisfying conditions and applications as mentioned above,RCCB with “ON-OFF” indicating device is considered suitable for isolation function.

1. Provides protection against earth fault/leakage current and function of isolation.

2. High short-circuit current withstand capacity.

3. Applicable to terminal and pin/fork type busbar connection.

4. Approved over-entering and down-entering connection.

5. Automatically disconnect the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity.

6. Independent of power supply and line voltage, and free from external interference, voltage fluctuation.

Model Name TORD4-63
Model Electro-magnetic type
Residual Current characteristic: A,AC
Pole No: 2P
Rated making and breaking capacity 630A
Rated current(A) 16, 25, 32, 40, 63, 80
Rated voltage 220V/380V
Rated frequency 50/60Hz
Rated residual operating current |△(A): 0.01
Rated residual non operating current |△ no: 0.5|△ n
Rated conditional short-circuit current inc: 3KA
Rated conditional residual short-circuit current |△c: 3KA
Tripping duration: Instantaneous tripping ≤0.1s
Residual tripping current range: 0.5||△n~|△n
Electro-mechanical endurance ≥4000 cycles
Connection capacity: Rigid conductor 25mm²
Connection terminal Screw terminal
Pillar terminal with clamp
Fastening torque 2.0 Nm
Installation On symmetrical DIN rail 35mm
Panel mounting